Đồng hồ vạn năng đo nhiệt độ Fluke 87-5
Thông số kỹ thuật:
+ DCV : 1000V / ±(0.05%+1)/10 µV
+ ACV : 1000V / ±(0.7%+2)/0.1 mV
+ DCA : 10A /±(0.2%+2)/ 0.01 µA
+ ACA : 10A /±(1.0%+2)/ 0.1 µA
+ Ω : 50 MΩ / ±(0.2%+1)/0.1Ω
+ C : 9,999 µF / ±(1%+2)/0.01 nF
+ F : 200 kHz /±(0.005%+1)/0.01 Hz
+ Duty Cycle : 99.9% / ±0.2% / 0.1%
+ Nhiệt độ : -200.0°C - 1090°C
+ Tính dẫn điện : 60nS / ±(1.0%+10)/ 0.01nS
Kiểm tra diode, liên tục
Kích thước : 201 x 98 x 52 mm
Khối lượng : 355 g
Hiện thị số
Phụ kiện : Que đo, đầu chíp, Pin 9V, HDSD, Que đo nhiệt độ
Specifications |
Voltage DC |
Maximum Voltage: |
1000V |
Accuracy: |
Fluke 83 V: ±(0.1%+1) |
|
Fluke 87 V: ±(0.05%+1) |
Maximum Resolution: |
Fluke 83 V: 100 µV |
|
Fluke 87 V: 10 µV |
|
Voltage AC |
Maximum Voltage: |
1000V |
Accuracy: |
Fluke 83 V: ±(0.5%+2) |
|
Fluke 87 V: ±(0.7%+2) True RMS |
AC Bandwidth |
Fluke 83 V: 5kHz |
|
Fluke 87 V: 20kHz* |
|
*with low pass filter; 3db @ 1kHz |
Maximum Resolution: |
0.1 mV |
|
Current DC |
Maximum Amps: |
10A (20 A for 30 seconds maximum) |
Amps Accuracy: |
Fluke 83 V: ±(0.4%+2) |
|
Fluke 87 V: ±(0.2%+2) |
Maximum Resolution: |
Fluke 83 V: 0.01 mA |
|
Fluke 87 V: 0.01 µA |
|
Current AC |
Maximum Amps: |
10A (20 A for 30 seconds maximum) |
Amps Accuracy: |
Fluke 83 V: ±(1.2%+2) |
|
Fluke 87 V: ±(1.0%+2) True RMS |
Maximum Resolution: |
0.1 µA |
|
Resistance |
Maximum Resistance: |
50 MΩ |
Accuracy: |
Fluke 83 V: ±(0.4%+1) |
|
Fluke 87 V: ±(0.2%+1) |
Maximum Resolution: |
0.1Ω |
|
Capacitance |
Maximum Capacitance |
9,999 µF |
Accuracy |
±(1%+2) |
Maximum Resolution |
0.01 nF |
|
Frequency |
Maximum Frequency |
200 kHz |
Accuracy |
±(0.005%+1) |
Maximum Resolution |
0.01 Hz |
|
Duty Cycle |
Maximum Duty Cycle |
99.9% |
Accuracy |
±(0.2% per khz +0.1%) |
Maximum Resolution |
0.1% |
|
Temperature Measurement |
Fluke 87 V, 87 V/E: |
-200.0°C - 1090°C |
|
-328.0°F - 1994.0°F |
|
excluding probe |
|
80 BK Temperature Probe |
|
-40.0°C - 260°C |
|
-40.0°F - 500°F, 2.2°C or 2% whichever is greater |
|
Conductance |
Maximum Conductance |
60.00 nS |
Accuracy |
±(1.0%+10) |
Maximum Resolution |
0.01 nS |
|
Diode |
Range: |
3 V |
Resolution: |
1 mV |
Accuracy: |
± (2 % + 1) |
|
Duty Cycle Range |
Accuracy: |
Within ± (0.2% per kHz + 0.1 %) |
|
Environmental Specifications |
Operating Temperature |
|
Storage Temperature |
|
Humidity (Without Condensation) |
|
0% - 90% (0°C - 35°C) |
|
0% - 70% (35°C - 55°C) |
|
Operating Altitude |
|
Safety Specifications |
Overvoltage category |
|
EN 61010-1 to 1000 V CAT III, 600V CAT IV |
|
Agency Approvals |
|
Mechanical & General Specifications |
Size |
|
201 x 98 x 52 mm (with holster) |
|
Weight |
|
Weigh With Holster and Flex-Stand |
|
Display |
Digital: |
6000 counts updates 4/sec. |
|
(Model 87 also has 19,999 counts in high-resolution mode.) |
Analog: |
32 segments, updates 40/sec. |
Frequency: |
19,999 counts, updates 3/sec at > 10 Hz. |
|
Warranty |
|
Battery Life |
Alkaline: |
~400 hours typical, without backlight |
|
Shock |
|
1 Meter drop per IEC 61010-1:2001 |
|
Vibration |
|
Per MIL-PRF-28800 for a Class 2 instrument |
|