Specifications |
|
|
Oscilloscope Bandwidth |
Fluke 124: |
40 MHz |
|
|
|
|
Dual input True RMS Meter |
|
Vdc, Vac, Vac+Vdc, Ohms,Continuity , Diode-test |
|
Current, °C, °F, Capacitance, dBV, dBM, Crest Factor, Touch Hold and Zeroset |
TrendPlot Recording |
|
Automatic vertical scaling and time compression. |
|
Display the actual, MIN, MAX and AVG reading. |
Cursors |
Fluke 125/124: |
∆T, 1/∆T, V, ∆V, rise- and fall time |
Real-time sample rate |
|
25 MS/s |
Equivalent sampling rate |
|
up to 2.5 GS/s (125, 124) or 1.25 GS/s (123). |
Inputs and digitizers |
|
2 |
Timebase range |
Fluke 125/124: |
20 ns - 1 min/div |
Fluke 123: |
10 ns - 1 min/div |
Input sensitivity |
|
5 mV - 500 V/div |
Trigger types |
|
Connect-and-View™, Free Run, Single Shot, Edge, Video, External |
Glitch capture |
|
40 ns |
Scope measurements |
|
Automatic measurements: 26 (all instruments) On top, Fluke 125 has additional measurement functions for Power (W), VA, VAR and Power Factor (PF) for single phase and balanced-three-phase (delta) power systems. |
Harmonics mode |
|
Fluke 125 has capbility to analyze the harmonics contents of power signals. See below for details. |
Maximum record length |
|
512 min/max pts per input |
Memory |
Fluke 125/124: |
20 screens and setups |
Fluke 123: |
10 screens and setups |
Additional Power measurement capabilities (Fluke 125 only) |
Measurement types: |
• |
Watt, |
• |
VA, |
• |
VAR, |
• |
Power Factor (PF) |
Power configuration: |
|
Single phase or balanced three-phase (delta-configuration) mains supply |
Voltage measurement |
|
Channel A; using STL120, voltage probe or direct input |
Current measurement |
|
Channel B, using i400s (included) or other compatible current clamp |
Current Clamp or Shunt sensitivity: |
|
0.1 / 1 / 10 / 100 / 1000 mV/A, 10 mV/mA and 400 mV/A. |
Harmonics Mode (Fluke 125 only) |
|
|
Converts waveform information into a harmonics display (using FFT processing) which shows the relative amplitudes of the 1st up to the 33rd harmonic |
Analyzed waveform: |
|
Voltage waveform(Ch.A), Current wavefrom (Ch.B) or Power (Ch.A x Ch.B), automatically generated. |
Harmonics Frequency range: |
|
DC up to 33rd harmonic (for fundamental up to 60 Hz); |
|
DC up to 24th harmonic (for fundamental up to 400 Hz). |
Display |
|
Bargraph showing 1st up to 33rd harmonic and DC; amplitude displayed in % relative to fundamental |
Measurements: |
|
Relative amplitude of individual harmonics; |
|
THD in %r or %f. |
Environmental Specifications |
Operating Temperature |
|
0 ºC to 50 ºC |
Storage Temperature |
|
-20 °C to +60 °C |
Operating Altitude |
|
3,000 m |
Mechanical & General Specifications |
Size |
|
232 x 115 x 50 mm |
Weight |
|
1.2 kg |
Warranty |
|
3-years on main instrument, 1-year on accessories |
Battery Life |
|
7 hrs using NiMH |
RS232/USB Interface |
|
Optically isolated via optional PM9080 or OC4USB for interfacing to Printer or PC |