Specifications |
Temperature |
Operating |
-10 °C to 55 °C (14 °F to 131 °F) |
Storage |
-30 °C to 60 °C (-22 °F to 140 °F) |
Relative humidity |
|
0 °C to 30 °C (32 °F to 86 °F): 90 % |
|
30 °C to 40 °C (86 °F to 104 °F): 75 % |
|
40 °C to 50 °C (104 °F to 122 °F): 45 % |
Altitude |
Operating |
2,000 m (approx. 6,561.6 ft) |
Storage |
10,000 m (approx. 32,808.4 ft) |
Battery type/life |
|
AAA (2); 40 hours |
Shock, vibration |
|
Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument |
Safety |
|
ISA-82.02.01 (IEC 61010-1 Mod) Second Edition, CAN/CSA-C22.2 No. 61010-1 Second Edition, IEC 61010 - 1 to 1000 V CAT III/600 V CAT IV |
|
Compliance to NFPA 70E* |
AC Bandwidth |
|
45 Hz to 66 Hz |
Maximum working voltage |
|
1000 V ac/dc |
Maximum measurable voltage |
|
600 V ac/dc |
Duty cycle |
|
Indefinitely for voltages up to 240 V |
|
For voltages between 240 V and 600 V the duty cycle is 30 s on / 300 s off |
|
For voltages above 240 V the tester must connect to a voltage source only for a MAXIMUM of 30 s and then disconnect for a MINIMUM of 300 s |
Voltage hazard LED |
|
LEDs turn on at voltages > 30 V ac/dc ± 35 % |
LED voltage indication levels |
|
12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 277 V, 480 V, 600 V |
LED voltage indication levels for Canadian version |
|
12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 347 V, 480 V, 600 V |
LEDs |
|
LEDs turn on between 90 % and 100 % of the indicated voltage on the LED, except for the 12 V LED which turns on between 50 % and 100 % |
LCD Accuracy on T+PRO only |
AC voltage |
± (3 % rdg + 2 digits) |
DC voltage |
± (2 % rdg + 2 digits) |
Resistance |
± (5 % rdg + 3 digits) |
LCD Resolution |
|
0.1 V for voltages < 50 V, 1 V for voltages ≥ 50 V |
|
0.01 kΩ for resistance measurement (For T+PRO Only) |
GFCI Test current |
|
100 V - 150 V @ 6 mA - 9 mA ac, 150 V - 240 V < 12 mA |
Standard input test current |
|
< 5 mA |
Size (HxWxL) |
|
1.3 in x 2.15 in x 7.6 in (3.3 cm x 5.46 cm x 19.3 cm ) |
Weight |
|
9.9 oz (0.28 kg) |